Detección de puntos calientes para la predicción de averías en las zonas de estudio I y II de la CNEL – EP, UNIDAD DE NEGOCIOS MANABI

  • I Navarrete
  • S Cano
  • N Balderramo
  • G Pico

Resumen

Abstract: This paper deals with the detection of PC that is presented in the lines of M / T nearshore for which the study is conducted in San Clemente and Crucita to 13.8 Kv feeders, which is determined as area I study, this study describes how to detect the existence of PC in the different elements of the structures forming the said power lines (zona study I). And in this other area are in populated areas and abundant pollution for which the study  is conducted in the feeders 3 (Portoviejo Centro) and 4 (Shopping-. Cdla Los Tamarindos) to 13.8 KV, which is determined as an area of study II. This study describes how to detect the existence of P.C in the different elements of the structures forming the said power lines.


Once the current state of the lines is described, it proceeds to determine the possible presence of P.C in each of the elements of the structures. In addition, statistical analysis will determine the items that need maintenance either preventive, predictive or corrective measures in order to implement measures that help to maintain proper lines  M /  T, and to  provide better quality  of electric service, and not have to regret lost electric power by joule effects shots in lines due to PC.


 Index Terms: maintenance, preventive measures, predictive measures, corrective measures, power lines.

Citas

1. A LABA, I. (2013). Guia de termograf ia para mantenimiento predictiv o "f lir". Obtenid o de http:// www. flir. es /hom e/
2. NE ITA DUARTE , L. Y. (2011). Principios Basicos de la Termograf ia y su Utilizacion Como Tecnic a Para Mantenimiento Pr edictivo.
3. GARCÉS -RESTREPO, J. C. (2012). Insp ecci on es Aer ea s de Lin eas de Transmisión con Alta Tecn ologia. Jornadas Tecnicas ISA.
4. In g-NAVARRE TE - GARC IA, I. (junio de 2015). DETECCIÓN DE PUNTOS CALIENTES EN LÍNEAS DE TRANSMISIÓN USANDO REDES NEURONALES ARTIFICIALES Y ELEM ENTOS DE INTE LIGENCIA ARTIFICIAL. Santiago, Cuba: universidad.
5. SOLÍS MORA, V. S. (2013). “DESARROLLO DE L MANTEN IM IEN TO PRED ICTIVO MED IANTE LA TÉCN ICA DE LA TERM OGR AFÍA PARA EVA LUAR E L
CORRECTO FUNCIONAM IEN TO DE LA SUBES TAC IÓN ORIEN TE Y ALIME N TADOR TO TORAS DE LA EMPRESA E LÉC TR ICA AMBA TO S. A.”. R IOBAM BA, Chimborazo , E cuador .
6. TERMOGRAFICA, C. S. (17 de JULIO d e 2011). INTEREMPR ESAS. Obt enid o de http://www.inter empr esa s.net/Quimica/Articulos/8677 - La inspeccion termografica en el mantenimiento predictivo de una planta. html.
7. CRESPO -QU INTERO, I. E. (2010). DESARROLLO DE UN MODE LO PARA LA LOCA LIZ AC IÓN DE FALLAS EN. UNAL, http://www.bdigital.una l.edu.co/2 028/1/71795342.20101.pd f.
8. INOCE NCIO ME LÉNDE Z, J. (0 3 de ma yo de 2012). Los métodos determinísticos como herramienta de la administración para la toma de decisiones. Obtenido de
9. PANE SSO-HERNÁNDE Z, A. F., & MORA-F LÓRE Z, J. J. (Dici emb re d e 2012). Loca li zación de Fa llas Monofásicas en Sistemas de Distribución Considerando el E fect o Capaci tivo y la N o Hom og en eidad de las Lín eas. Vol. 2 (Nº. 52, 2012), http://dialn et.uniri oja.es/s er vl et/arti culo?codig o=4271870.
10. OSP INA-NORE ÑA, J. E., & DE JESÚS LEMA, Á. (2011). TR A TAM IE N TO E S TADÍS TICO PARA INDICADORES CUANTITA TIVOS DE IMPACTOS, APLIC ADOS A
LINE AS DE TRANSMIS IÓN E LÉC TR ICA. U NAL, http://www. revistas.una l.edu. co/i nd ex.php/r efam e/articl e/ vi ew/24252/24876.
11. POYATO, R. (2012). Termograf ia en Sistemas de Distribrucion Eléctrica "FLUKE". Obtenid o de http://pt .rs - onlin e.com/ es/pd f/RSF LU KEE LE C TR IC IDAD02.pdf
12. Escotto, L. (2010). Mantenimiento correctivo . Obtenid o de http://www.monogra fias.com/trab ajos -pdf5/mant enimi ento- corr ecti vo/mant enimi ent o- corr ect ivo.shtml
13. http://www.monogra fias.com/trab ajos96/met odos - determinis ticos -herrami enta-administracion - decision es/met od os -det erministicos-h errami enta- administracion -decision es. shtml
14. León, A. V. (2014). DETECCIÓN Y MEDIC IÓN DE PUNTOS C ALIE N TES. M exico. Obt enid o de https://calidadt esla. fil es. wordpres s.com/2014 /06/ capitulo - 17.pdf
15. Pérez, C. D. (2015). Crecimi ent o d e algas sobre aislador es de m edia t ensión y su impacto sob r e el desemp eñ o eléct r ico. Obtenid o de http://revis tas.udistrital. edu .co/ ojs/ind ex.php/ Tecnura/art icl e/ vi ew/9605
16. Saavedra, T. J. (2007). REVISIÓN DE LA EFEC TIVIDAD DEL PLAN ANUAL DE MANTENIMIENTO PREVEN TIV O DE LA RED DE DISTR IBUCIÓN DE ENELCO A 13,8 KV. Obtenid o de http:/ /t esis.ula. ve/p regrad o/td e_arqui vos /9/ TDE -2012-07-10 T01:13:40 Z-
Publicado
2016-01-11
Sección
Artículos