Análisis del momento curvatura en vigas principales de hormigón atravesadas por vigas metálicas

  • Yordy Mieles Bravo
  • Julio Hernández Caneiro

Resumen

Considerations for the treatment of concrete beams crossed by secondary steel beams is discussed. Even where data are available, they have been used beams of its kind since 2013, especially in the province of Manabí, Ecuador. It is known so far four buildings in which this solution has been used. Besides construction of such projects in the Republic of Cuba, in the area of Mariel. However, structural analysis of this type of construction has been markedly empirical being.


The scope of the recommendations of the American Concrete Institute (ACI) for embedded in concrete, and the use of these regulatory provisions to the location of the opening in beams under study is discussed in this paper.


To analyze the behavior of the cross section, the method of moment versus curvature  (M-ϕ ) is used, modeling the behavior of concrete with the proposed linear pattern and tri Mander model for the behavior of the steel by ETABS software. It is evident in the analysis of moment decreases the ability to invade the hollow block compressions. If it is a steel beam crosses and invades the block compressions improves moment but in cross section, requiring another type of treatment for the overall performance level of the longitudinal section.


Index Terms Momento curvatura, hormigón confinado, resistencia, ductilidad.

Citas

Aguiar R. (2003). Análisis sísmico por desempeño. Quito: ESPE.
Aguiar R. (2012). Vulmerabilidad sísmica de un edificio de 16 pisos: relación momento curvatura. II Congreso de Ciencia y Técnología (pág. 1 a 13). Quito: ESPE.
American-Concrete-Institute. (2010). Recomendaciones para el Diseño de Conecciones Viga-Columna en Estructuras Monolíticas de Concreto Reforzado. Farmigton Hills MI: ACI.
American-Concrete-Institute. (2014). Building Code Requeriments for Structural Concrete 318R 14. Farmintong Hills MI: ACI.
Anandavalli N, R. J. (2013). Static Response of Steel-Concrete Sandwich Beam with BI-Directionally Inclined Connector. American Journal of Civil Engineering and Architecture, Vol. 1, 15-20.
ASTM C469. (21 de 3 de 2015). Standard test method for static and modulus of elasticity and poisson’s ratio of concrete in compression. Obtenido de www.astm.org: www.astm.org
Cabrera N. (2011). Influencia de las aberturas transversales, en la resistencia a corte y flexión en vigas de concreto reforzado. Bogotá: Universidad Nacional de Colombia.
Chung H, Y. H. (2002). Stress-strain curve of laterally confined concrete. Eng. Struct., 1153-1163.
Hernández H, B. J. (2014). Estudio del comportameinto de vigas compuestas de hormigón y acero mediante simulación numérica. Revista Ingeniería de Construcción, Vol 29 N. 1.
Hernández J, H. J. (2013). Hormigón Estructural Diseño por Estados Límites. La Habana: Félix Varela.
Herrera R. (2012). Conexiones para Elementos Compuestos. Santiago: Universidad de Chile.
Husem M, P. S. (2006). Investigation of stress-strain models for confined high strength concrete. Sadhana, 243-252.
Mander B, P. M. (1988). Theoretical stress-strain model for confined concrete. Journal of Structural Engineering, Vol 114, No. 8 pp 22686.
Mander J. (1988). Seismic design of bridge piers. New Zealand: Ph.D Thesis, Department of Civil Engineering, University of Canterbury.
Mieles Y, C. J. (2015). Comportamiento de secciones de hormigón sometidas a flexión reforzadas con barras de acero o prf. Primer Taller Nacional de Seguridad de las Estructuras, Guardalavaca, Holguin, (págs. 1-15). Guardalavaca.
Nagashima T, S. S. (1992). Monotonic axial compression test on ultra-high-stenght concrete tied columns. 10th Word COnference on Eartquake Engineering, (págs. 2983-2988). Rotterdam.
Nilson A, D. D. (2010). Desing of Concrete Structures. New York: Mc Graw Hill.
Norma Ecuatoriana de la Construcción. (2014). Estructuras de Hormigón Armado NEC-SE-HM. Quito: Ministerio de Desarrollo Urbano y Vivienda.
Panés A. (2011). Simulación numérica de la interconexión de corte de vigas mixtas de acero de alta resistencia y hormigón UHPC. Obras y Proyectos, 12, 16-25.
Park R, P. M. (1982). Ductility of square-confined columns. J. Struct. Div., 929-950.
Roy H, S. M. (1964). Ductility of concrete. In Flexual Mechanics of Reinforced COncrete. American Concrete Institute/American Society of Civil Engineers, 213-224.
Saatcioglu M, R. S. (1992). Strength and ductility of confined concrete. J. Struct. Div., 118: 1590-1607.
Sargin M. (1971). Stress-strain relationships for concrete an the analysis of structural concrete sections. Solid Mechanics Division.
Vargas G, G. J. (2005). Procedimiento para obtener gráficas momento-curvatura en vigas de concreto reforzado. Ingeniería, (9-1) 2005 37-47.
Publicado
2017-01-09
Sección