Adquisición de señales balistocardiográficas con Arduino
DOI:
https://doi.org/10.33936/riemat.v7i1.4837Palabras clave:
accelerometer, BCG, gyroscope, Arduino, RealTermResumen
The noninvasive Balistocardiogram (BCG) signal is the recording of body movements due to heartbeat and blood flow through major arteries. This signal provides enough information to calculate the heart rate and its variations over time. The present paper proposes the design of a prototype of a low-cost electronic system to record the BCG signals acquired by means of a triaxial accelerometer and gyroscope. For the design of the system, an Arduino development board, the 9-axis MPU-9250 sensor (accelerometer, gyroscope and magnetometer), and the free software RealTerm are used. The system is connected by a USB port to a personal computer from where the entire system is governed.
A model of the system was built and tested successfully with arbitrary signals, checking the correct functioning of the system and recording the data in a text file for later analysis.
Descargas
Citas
Hernández Hurtado, Zuley Camila; Díaz Álvarez, Vivian Paola. Medición no-invasiva e indirecta de la frecuencia cardíaca de pacientes usando sensores de bajo costo. Trabajo de diploma. Universidad del Rosario; Bogotá, Colombia; 2021.
. Barón, Alberto. Balistocardiógrafo: historia de un instrumento para medir en forma indirecta el desempeño del corazón. Rev Colomb Cardiol. febrero de 2009; Vol. 16 No.1.
. Hernández Urrea, Marc. Implementación y caracterización de un sistema inalámbrico para la medida de parámetros fisiológicos de manera no invasiva. Trabajo de diploma al grado en Ingeniería de Sistemas de Telecomunicaciones. Universidad Politécnica de Catalunya; 2016.
. Zuluaga Gómez, Juan Pablo. Desarrollo de un sistema basado en acelerometría para la captación y análisis en Matlab de señales precordiales usando Sismocardiografía. Proyecto de grado para optar al título de Ingeniero Mecatrónica; Universidad Autónoma del Caribe; Barranquilla; 2015.
. Brink, Mark; Müller Christopher. Contact-free measurement of heart rate, respiration rate, and body movements during sleep. Behavior Research Methods, 2006, 38 (3), 511-521.
] Varri, Alpo; Viik, Jari; Hyttinem, Jari. Estudios balistocardiográficos con sensores de aceleración y película electromecánica. 2009. Disponible en: https://www.researchgate.net/publication/26773049
Ortega Delfino, Yoangel. Determinación aproximada de la frecuencia cardiaca en el Balistocardiograma. Tesis en opción al título de Ingeniero Biomédico. Universidad de Oriente; Santiago de Cuba; 2019.
. Sadek, Ibrahim; Biswas, Jit; Abdulrazak, Bessam. Ballistocardiogram signal processing: a review. Health Inf Sci Syst, Vol. 7 No. 10, 2019; Disponible en: https://doi.org/10.1007/s13755-019-0071-7
. Banzi, Massimo. Manual de Programación. 2007. Disponible en: http://www.arduino.cc/en/Booklet/HomePage 44
. Herrera Mata, Stephany Elizabeth. Diseño electrónico de un sistema de estimación de orientación basado en sensores inerciales como aplicación en rehabilitación motriz. Tesis para obtener el título de Ingeniero Eléctrico Electrónico. Universidad Nacional Autónoma de México; 2017.
. Atmega328. Wikipedia. 2021. Disponible en: https://es.wikipedia.org/w/index.php?title=Atmega328&oldid=136603139
. Libro básico de Arduino. Bogotá, Colombia; 2012. Disponible en: www.tiendaderobotica.com
. MPU-9250 Product Specification Revision 1.1. 2016. Disponible en: www.invensense.com
. Abascal Falagan, Cecilia. Sistema de posicionamiento y localización de un Robot Autónomo en superficies exteriores. Tesis para acceder al título de graduada en Ingeniería Eléctrica Industrial y Automática. Universidad de Cantabria; 2021.
L, Albert. Arduino, data visualization. How to plot data from the Arduino COM Serial Port. 2020.
Descargas
Publicado
Número
Sección
Licencia
Derechos de autor 2022 Dayana Sánchez Villalón, Fernando Valdés, Yolanda Andrial, Angela Giralt

Esta obra está bajo una licencia internacional Creative Commons Atribución-NoComercial-CompartirIgual 4.0.